Experts has a new look! Let us know what you think of the updates.

Provide feedback
Home
Scholarly Works
Effect of Off‐Pump Coronary Artery Bypass Grafting...
Conference

Effect of Off‐Pump Coronary Artery Bypass Grafting on Risk‐Adjusted and Cumulative Sum Failure Outcomes After Coronary Artery Surgery

Abstract

BACKGROUND AND AIM: We have shown that cumulative sum (CUSUM) failure analysis may be more sensitive than standard statistical methods in detecting a cluster of adverse patient outcomes after cardiac surgical procedures. We therefore applied CUSUM, as well as standard statistical techniques, to analyze a surgeon's experience with off-pump coronary artery bypass grafting (OPCAB) and on-pump procedures to determine whether the two techniques have …

Authors

Novick RJ; Fox SA; Stitt LW; Kiaii BB; Abu‐Khudair W; Lee A; Benmusa A; Swinamer SA; Rayman R; Menkis AH

Volume

17

Pagination

pp. 520-528

Publisher

Hindawi

Publication Date

11 2002

DOI

10.1046/j.1540-8191.2002.01008.x

Conference proceedings

Journal of Cardiac Surgery

Issue

6

ISSN

0886-0440