abstract
- There are numerous scenarios where radioactive particulates can be displaced by external forces. For example, the detonation of a radiological dispersal device in an urban environment will result in the release of radioactive particulates that in turn can be resuspended into the breathing space by external forces such as wind flow in the vicinity of the detonation. A need exists to quantify the internal (due to inhalation) and external radiation doses that are delivered to bystanders; however, current state-of-the-art codes are unable to calculate accurately radiation doses that arise from the resuspension of radioactive particulates in complex topographies. To address this gap, a coupled computational fluid dynamics and Monte Carlo radiation transport approach has been developed. With the aid of particulate injections, the computational fluid dynamics simulation models characterize the resuspension of particulates in a complex urban geometry due to air-flow. The spatial and temporal distributions of these particulates are then used by the Monte Carlo radiation transport simulation to calculate the radiation doses delivered to various points within the simulated domain. A particular resuspension scenario has been modeled using this coupled framework, and the calculated internal (due to inhalation) and external radiation doses have been deemed reasonable. GAMBIT and FLUENT comprise the software suite used to perform the Computational Fluid Dynamics simulations, and Monte Carlo N-Particle eXtended is used to perform the Monte Carlo Radiation Transport simulations.