Conference
Adagrad Algorithm based Optimal Slot-pole Selection for Reduced Inductance Harmonics in Concentrated Wound Multiphase PMSM.
Abstract
Fractional slot concentrated windings (FSCW) permanent magnet synchronous machines (PMSM) have high content of space harmonics in the magnetomotive force (MMF) due to which the harmonic inductance is much larger than the magnetizing inductance [1] . These inductance harmonics lead to high torque ripple and low power factor. In case of FSCW, the coils are full pitched and cannot be chorded like in distributed windings to reduce inductance …
Authors
Dhulipati H; Ghosh E; Mukundan S; Tjong J; Kar NC
Volume
00
Pagination
pp. 1-1
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Publication Date
April 27, 2018
DOI
10.1109/intmag.2018.8508112
Name of conference
2018 IEEE International Magnetics Conference (INTERMAG)