Home
Scholarly Works
High Precision Mechanical Components for Soft...
Conference

High Precision Mechanical Components for Soft X‐ray Beamline: Engineering Goal and Testing Results

Abstract

As the emittance of SR rings approaches the diffraction limit for soft x‐rays, one requires not only excellence in design and performance of the optical elements, but also precision and performance of mechanical components, such as mirror manipulators, monochromator scanners and exit slits. We will present simple but efficient solutions for the mechanical systems of this type, commonly encountered in soft x‐ray beamlines. These solutions have been implemented and their performance evaluated with test results from the spectromicroscopy beamline at the Canadian Light Source.

Authors

Kaznacheyev KV; Karunakaran C; Sitnikov A; Loken D; Warwick T; Nagy M; Hitchcock AP

Volume

879

Pagination

pp. 730-733

Publisher

AIP Publishing

Publication Date

January 19, 2007

DOI

10.1063/1.2436166

Name of conference

AIP Conference Proceedings

Conference proceedings

AIP Conference Proceedings

Issue

1

ISSN

0094-243X
View published work (Non-McMaster Users)

Contact the Experts team