An improved solid-phase enzyme immunoassay (EIA) with Chlamydia trachomatis L2 434/Bu elementary bodies was developed for the measurement of immunoglobulin M (IgM) antibody to C. trachomatis in serum. Comparison of EIA and microimmunofluorescence IgM antibody titers of 156 serum samples revealed an EIA sensitivity and specificity of 100% for infants, but reduced sensitivity (85%) and specificity (76%) for sera from adults. Sera containing IgM …