Home
Scholarly Works
Performance in fire of FRP-strengthened and...
Journal article

Performance in fire of FRP-strengthened and insulated reinforced concrete columns

Abstract

This research investigates the fire performance of one circular and one square reinforced concrete column strengthened with a fibre reinforced polymer (FRP) wrap and covered with a unique supplemental fire protection system. An experimental full-scale fire resistance test was conducted at the National Research Council of Canada. The insulated and strengthened FRP wrapped columns were exposed to the ULC-S101 standard fire and both columns obtained fire endurance ratings of over 4 h. Details of the fire endurance experiment on both columns are described in this paper. Additionally, numerical models developed specifically for circular and square columns are validated against the experimental results.

Authors

Cree D; Chowdhury EU; Green MF; Bisby LA; Bénichou N

Journal

Fire Safety Journal, Vol. 54, , pp. 86–95

Publisher

Elsevier

Publication Date

January 1, 2012

DOI

10.1016/j.firesaf.2012.08.006

ISSN

0379-7112

Labels

Fields of Research (FoR)

View published work (Non-McMaster Users)