Experts has a new look! Let us know what you think of the updates.

Provide feedback
Home
Scholarly Works
A three-dimensional tunnel model for calculation...
Journal article

A three-dimensional tunnel model for calculation of train-induced ground vibration

Abstract

The frequency range of interest for ground vibration from underground urban railways is approximately 20 to 100Hz. For typical soils, the wavelengths of ground vibration in this frequency range are of the order of the spacing of train axles, the tunnel diameter and the distance from the tunnel to nearby building foundations. For accurate modelling, the interactions between these entities therefore have to be taken into account. This paper …

Authors

Forrest JA; Hunt HEM

Journal

Journal of Sound and Vibration, Vol. 294, No. 4-5, pp. 678–705

Publisher

Elsevier

Publication Date

July 2006

DOI

10.1016/j.jsv.2005.12.032

ISSN