PURPOSE: Synthetic grafts have been increasingly used for complex vascular reconstructions in patients with limited autologous vein availability. Materials currently in use induce increased stenosis and graft thrombosis compared with autologous vein, especially in smaller vessels. We examined whether grafts constructed of a porous biodegradation-resistant polycarbonate polyurethane (PU) exert better biocompatibility in terms of faster …