Conference
Direct Production of 99mTc via 100Mo(p,2n) on Small Medical Cyclotrons
Abstract
From the efforts of a number of Canadian institutions and private industry collaborations, direct production of 99mTc using medical cyclotrons has recently been advanced from a 1970's academic exercise to a commercial, economically viable solution for regional production. Using GE PETtrace 880 machines our team has established preliminary saturated yields of 2.7 GBq/μA, translating to approximately 174 GBq after a 6 hour irradiation. The team …
Authors
Schaffer P; Bénard F; Bernstein A; Buckley K; Celler A; Cockburn N; Corsaut J; Dodd M; Economou C; Eriksson T
Volume
66
Pagination
pp. 383-395
Publisher
Elsevier
Publication Date
2015
DOI
10.1016/j.phpro.2015.05.048
Conference proceedings
Physics Procedia
ISSN