Experts has a new look! Let us know what you think of the updates.

Provide feedback
Home
Scholarly Works
Calibration factors for the SNOOPY – NP-100...
Conference

Calibration factors for the SNOOPY – NP-100 neutron dosimeter

Abstract

Within CANDU nuclear power facilities, only a small fraction of workers are exposed to neutron radiation. For these individuals, roughly 4.5% of the total radiation equivalent dose is the result of exposure to neutrons. When this figure is considered across all workers receiving external exposure of any kind, only 0.25% of the total radiation equivalent dose is the result of exposure to neutrons. At many facilities, the NP-100 neutron …

Authors

Moscu DF; McNeill FE; Chase J

Volume

263

Pagination

pp. 329-331

Publisher

Elsevier

Publication Date

October 2007

DOI

10.1016/j.nimb.2007.04.130

Conference proceedings

Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms

Issue

1

ISSN

0168-583X