Journal article
Effect of Accelerated Cooling on Linepipe Steel Mill Scale and Resulting Localized Corrosion Susceptibility
Abstract
The structure and composition of mill scale on linepipe steel formed with and without accelerated cooling conditions (ACC) was investigated and correlated to localized corrosion susceptibility. The mill scale structure/composition was investigated using scanning electron microscopy equipped with x-ray energy dispersive spectroscopy and electron backscatter diffraction, as well as x-ray diffraction. Localized dissolution of the mill scale was …
Authors
Filice SE; McDermid JR; Kish JR
Journal
Corrosion, Vol. 78, No. 2, pp. 168–180
Publisher
Association for Materials Protection and Performance (AMPP)
Publication Date
February 1, 2022
DOI
10.5006/3936
ISSN
0010-9312