An experimental investigation is reported for medium-temperature, wickless, small-diameter heat pipes charged with environmentally sound and commercially available working fluids. The wickless heat pipes (thermosyphons) studied have many applications in heat recovery systems since their operational temperature range is between 200°C and 450°C. The heat pipes investigated had an internal diameter of 6 mm and a length of 209 mm. The lengths of …

Authors

Jouhara H; Robinson AJ

Volume

30

Pagination

pp. 1041-1048

Publisher

Taylor & Francis

Publication Date

November 2009

DOI

10.1080/01457630902921113

Conference proceedings

Heat Transfer Engineering

Issue

13

ISSN

0145-7632