Conference
The influence of design ductility capacity on the seismic performance of medium height reinforced concrete frame buildings
Abstract
This paper describes an investigation into the seismic performance of a six storey moment resisting frame structure located in Vancouver and designed and detailed in accordance with the seismic provisions of the National Building Code of Canada (1995). Both pushover and dynamic analyses are conducted using an inelastic model of the structure as designed and detailed. The structural performance of frames designed with different ductility …
Authors
Heidebrecht AC; Naumoski N
Volume
SP-197
Pagination
pp. 239-264
Publication Date
April 1, 2002
Conference proceedings
American Concrete Institute ACI Special Publication
ISSN
0193-2527