Abstract
This paper presents a study on monitoring tool failure in drilling using vibration signature analysis techniques. Time and frequency domain signature features are developed which are sensitive to tool breakage. The ability of these features to detect drill breakage was verified experimentally. The drilling tests were performed using 3 mm diameter high speed steel twist drills, and cast iron workpieces. The results confirm the effectiveness and …
Authors
El-Wardany TI; Gao D; Elbestawi MA
Book title
Proceedings of the Thirty-First International Matador Conference
Pagination
pp. 249-254
Publisher
Springer Nature
Publication Date
1995