Abstract
The main function of the concrete containment structures is to prevent radioactive leakage to the environment in case of a loss of coolant accident (LOCA). The Canadian Standard CSA N287.6 (2011) proposes periodic inspections, i.e., pressure testing, in order to assess the strength and design criteria of the containment (proof test) and the leak tightness of the containment boundary (leakage rate test). During these tests, the concrete strains …
Authors
Balomenos GP; Pandey MD
Journal
Nuclear Engineering and Design, Vol. 311, , pp. 50–59