Journal article
Resistive Load Detection during Passive Ventilation
Abstract
By using standard psychophysical techniques resistive load detection was estimated in five normal subjects during spontaneous breathing and during passive ventilation in a Drinker respirator. 2. During assisted ventilation a gross deterioration in resistive load detection occurred. 3. The findings imply that active respiratory muscle contraction plays an essential role in the detection of added resistive loads.
Authors
Killian KJ; Mahutte CK; Campbell EJM
Journal
Clinical Science, Vol. 59, No. 6, pp. 493–495
Publisher
Portland Press
Publication Date
December 1, 1980
DOI
10.1042/cs0590493
ISSN
0143-5221