Abstract
The active or passive decoupling method has to be utilized to deal with the second-order harmonic existing in the DC-bus of the grid-tied single-phase inverters. Compared with the active decoupling method, the passive decoupling method is simpler, cheaper and more reliable. The electrolytic capacitors are usually used in the DC-bus as typical passive decoupling components. The film capacitors can be added in parallel with the electrolytic …