Journal article
Corrosion of High-Alloy Superheater Tubes in a Coastal Biomass Power Boiler
Abstract
Metallurgical examinations were conducted on a set of damaged high-alloy (Type 310H [UNS S31009] stainless steel and Alloy 625 [UNS N66250] weld overlay) superheater tubes removed from a coastal fluidized bed biomass power boiler, to better understand the degradation mode. Active oxidation (gas-solid reaction occurring underneath the chloride-containing fi reside deposit) was found to be the mechanism responsible for the significant loss in …
Authors
Kish JR; Reid C; Singbeil DL; Seguin R
Journal
Corrosion, Vol. 64, No. 4, pp. 356–366
Publisher
Association for Materials Protection and Performance (AMPP)
Publication Date
April 1, 2008
DOI
10.5006/1.3278479
ISSN
0010-9312