Conference
Composite Control of DOC-out Temperature for DPF regeneration
Abstract
Control of Diesel Oxidation Catalyst (DOC) outlet temperature is critical for the downstream Diesel Particulate Filter (DPF) regeneration. However, the disturbances, delay time variation and model uncertainties make it difficult to control DOC outlet temperature. A Composite Controller (CC) based on modified Active Disturbance Rejection Control (mADRC) with delay-time adaptation was proposed for DOC-out temperature control in this paper. The …