3-D Sub-Domain Analytical Model to Calculate Magnetic Flux Density in Induction Machines With Semiclosed Slots Under No-Load Condition

Abstract

In this paper, a novel 3-D sub-domain analytical model is developed to determine magnetic flux distribution in single-cage induction machines (IMs) with skewed rotor bars under no-load condition in an effort to more detailed analysis of spatial harmonics. The proposed model, along with an optimization algorithm, is as an alternative solution to finite-element analysis (FEA) in optimizing the geometry of IMs. The analytical method is based on …

Authors

Mollaeian A; Ghosh E; Dhulipati H; Tjong J; Kar NC

Volume

53

Pagination

pp. 1-5

Publisher

Institute of Electrical and Electronics Engineers (IEEE)

Publication Date

June 1, 2017

DOI

10.1109/tmag.2017.2658543

Conference proceedings

IEEE Transactions on Magnetics

Issue

6

ISSN

0018-9464