Home
Scholarly Works
Imaging cerebral microbleeds using susceptibility...
Journal article

Imaging cerebral microbleeds using susceptibility weighted imaging: One step toward detecting vascular dementia

Abstract

PURPOSE: To monitor changes in the number of cerebral microbleeds (CMBs) in a longitudinal study of healthy controls (HC) and mild-cognitively impaired (MCI) patients using susceptibility weighted imaging (SWI). MATERIALS AND METHODS: SWI was used to image 28 HC and 75 MCI patients annually at 1.5 Tesla over a 4-year period. Magnitude and phase data were used to visualize CMBs for the first and last scans of 103 subjects. RESULTS: Preliminary analysis revealed that none of the 28 HC had more than three CMBs. In the 75 MCI patients, five subjects had more than three CMBs in both first and last scans, while one subject had more than three bleeds only in the last scan. In five of these six MCI patients, the number of CMBs increased over time and all six went on to develop progressive cognitive impairment (PCI). Of the 130 total CMBs seen in the last scans of the six MCI cases, most were less than 4 mm in diameter. CONCLUSION: SWI can reveal small CMBs on the order of 1 mm in diameter and this technique can be used to follow their development longitudinally. Monitoring CMBs may be a means by which to evaluate patients for the presence of microvascular disease that leads to PCI.

Authors

Ayaz M; Boikov AS; Haacke EM; Kido DK; Kirsch WM

Journal

Journal of Magnetic Resonance Imaging, Vol. 31, No. 1, pp. 142–148

Publisher

Wiley

Publication Date

January 1, 2010

DOI

10.1002/jmri.22001

ISSN

1053-1807

Contact the Experts team