Conference
Stator Winding Failures: Contamination, Surface Discharge, Tracking
Abstract
Stator winding failures are generally attributed to groundwall or turn insulation failures. The failure mechanism involves the gradual development of a weakness in the insulation. This weakness is usually caused by a trapped void that is continuously enlarging due to ever-increasing corona or partial discharge activity. The failure mode is from the inside out. Recent studies of failures in actual machines, and of coils on voltage endurance …
Authors
Dymond JH; Stranges N; Younsi K; Hayward JE
Volume
38
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Publication Date
2002
DOI
10.1109/28.993182
Conference proceedings
IEEE Transactions on Industry Applications
Issue
2
ISSN