Home
Scholarly Works
Reliability and comparison of acromion assessment...
Journal article

Reliability and comparison of acromion assessment techniques on X-ray and magnetic resonance imaging (reliability of acromion assessment techniques).

Abstract

OBJECTIVE: To determine the reliability and correlation of plain radiography and magnetic resonance imaging (MRI) in the assessment of acromion morphology. MATERIALS AND METHODS: Acromion morphology was assessed using the lateral acromion angle (LAA) and the acromion-humeral interval (AHI). Thirty patients who had X-rays and MRI for impingement syndrome were included. Six blinded observers assessed the acromion morphology subjectively and objectively. RESULTS: Neither acromion assessment technique demonstrated a positive correlation (kappa and intraclass coefficient < 0.55) between X-ray and MRI. Both techniques were reliable (kappa and intraclass coefficient > 0.55) when measured objectively by experienced observers. CONCLUSION: The LAA and the AHI are both reliable acromion assessment techniques on X-ray and MRI when measured objectively and by experienced observers.

Authors

Viskontas DG; MacDermid JC; Drosdowech DS; Garvin GJ; Romano WM; Faber KJ

Journal

Canadian Association of Radiologists Journal, Vol. 56, No. 4, pp. 238–244

Publication Date

October 1, 2005

ISSN

0846-5371

Contact the Experts team