Journal article
Are Volar Locking Plates Superior to Percutaneous K‐wires for Distal Radius Fractures? A Meta‐analysis
Abstract
BACKGROUND: Distal radius fractures are common, costly, and increasing in incidence. Percutaneous K-wire fixation and volar locking plates are two of the most commonly used surgical treatments for unstable dorsally displaced distal radius fractures. However, there is uncertainty regarding which of these treatments is superior.
QUESTIONS/PURPOSES: We performed a meta-analysis of randomized controlled trials to determine whether patients treated …
Authors
Chaudhry H; Kleinlugtenbelt YV; Mundi R; Ristevski B; Goslings JC; Bhandari M
Journal
Clinical Orthopaedics and Related Research®, Vol. 473, No. 9, pp. 3017–3027
Publisher
Wolters Kluwer
Publication Date
9 2015
DOI
10.1007/s11999-015-4347-1
ISSN
0009-921X
Associated Experts
Fields of Research (FoR)
Medical Subject Headings (MeSH)
Biomechanical PhenomenaBone PlatesBone WiresChi-Square DistributionEquipment DesignFracture Fixation, InternalHumansOdds RatioPostoperative ComplicationsRadius FracturesRandomized Controlled Trials as TopicRange of Motion, ArticularRecovery of FunctionRisk FactorsTreatment OutcomeWrist InjuriesWrist Joint