We have compared biventricular Pressure-Volume Analysis in Swine with Contrast-Enhanced Computed Tomography During Transient Pressure Overload. Pressure overload was induced by 60-minute intravenous infusion of phenylephrine (PE; 300 ug/min). Biventricular PV analysis provided reasonably accurate measurements of ventricular volumes compared with contrast-enhanced cardiac multi-detector computed tomography (MDCT). Employing this approach during transient PE infusion demonstrated persistent chamber dilatation and systolic dysfunction in the LV, but not RV, consistent with stretch-induced stunning caused by an acute elevation in preload.

Authors

Konecny F; Smith C; Techiryan G; Canty Jr. JM; Weil BR