Journal article
The optimization of an energy-dispersive X-ray diffraction system for potential clinical application
Abstract
In the past decade, energy-dispersive X-ray diffraction (EDXRD) has been used to identify the nature of tissues. However, these systems have limited clinical use because of problems such as the long measurement times. In this study, the relation between various setup parameters and some performance specifications such as sensitivity, spatial resolution and momentum transfer resolution were assessed using both geometrical calculations and …
Authors
Chaparian A; Oghabian MA; Changizi V; Farquharson MJ
Journal
Applied Radiation and Isotopes, Vol. 68, No. 12, pp. 2237–2245
Publisher
Elsevier
Publication Date
12 2010
DOI
10.1016/j.apradiso.2010.07.002
ISSN
0969-8043