Design and eco-technoeconomic analyses of SOFC/GT hybrid systems accounting for long-term degradation effects
Abstract
This study compares two SOFC/GT (solid oxide fuel cell with gas turbine) hybrid systems to that of two standalone SOFC systems via eco-technoeconomic analyses that account for long-term degradation effects. Four cases were examined: 1) standalone SOFC plant without a steam bottoming cycle; 2) standalone SOFC plant with a steam bottoming cycle; 3) SOFC/GT hybrid plant without a steam bottoming cycle; and 4) SOFC/GT with a steam bottoming cycle. …
Authors
Lai H; Harun NF; Tucker D; Adams TA
Journal
International Journal of Hydrogen Energy, Vol. 46, No. 7, pp. 5612–5629
Publisher
Elsevier
Publication Date
January 2021
DOI
10.1016/j.ijhydene.2020.11.032
ISSN
0360-3199