Journal article
Uptake and Release of a Multipurpose Solution Biocide (MAP-D) From Hydrogel and Silicone Hydrogel Contact Lenses Using a Radiolabel Methodology
Abstract
PURPOSE: The purpose of this study was to evaluate the uptake and release of radiolabelled myristamidopropyl dimethylamine (MAP-D) on reusable daily wear contact lenses (CLs) over 7 days.
METHODS: Three silicone hydrogel (SH) CL materials (lotrafilcon B, balafilcon A, senofilcon A) and two conventional hydrogel (CH) materials (etafilcon A, omafilcon A) were tested. A short-term (experiment 1, N=4) and a longer-term (experiment 2, N=3) study was …
Authors
Yee A; Phan C-M; Chan VWY; Heynen M; Jones L
Journal
Eye & Contact Lens Science & Clinical Practice, Vol. 47, No. 5, pp. 249–255
Publisher
Wolters Kluwer
Publication Date
May 2021
DOI
10.1097/icl.0000000000000724
ISSN
1542-2321