Journal article
Theoretical and Experimental Investigation of Subcooled Flashing Flow through Simulated Steam Generator Tube Cracks
Abstract
Flow models and experiments were developed to predict the choking flow of subcooled flashing water through steam generator tube crack. Experiments were conducted for vessel pressures up to 7 MPa with various subcoolings through 7 sets of simulated crack geometries with channel length to diameter ratios from 1.3 to 2, and channel length of 1.3 mm. Mass flux data with respect to subcooling are presented for all seven sets of crack specimens. As …
Authors
Vadlamani RA; Revankar ST; Riznic JR
Journal
Heat Transfer Engineering, Vol. 40, No. 7, pp. 524–536
Publisher
Taylor & Francis
Publication Date
April 21, 2019
DOI
10.1080/01457632.2018.1436396
ISSN
0145-7632