A Novel Fault-Tolerant Technique for Active-Neutral-Point-Clamped Inverter Using Carrier-Based PWM

Abstract

This paper presents a novel fault-tolerant method for activeneutral-point-clamped (ANPC) inverter using a modified carrier-based pulsewidth modulation. At a fault event, the ANPC inverter is divided into subinverters, and the modulating signal is modified to two modulating signals. The modified modulating signals are used to control the subinverters and allow continuous operation of the three-level ANPC inverter during faulty conditions even up …

Authors

Azer P; Ouni S; Narimani M

Journal

IEEE Transactions on Industrial Electronics, Vol. 67, No. 3, pp. 1792–1803

Publisher

Institute of Electrical and Electronics Engineers (IEEE)

DOI

10.1109/tie.2019.2903764