Experts has a new look! Let us know what you think of the updates.

Provide feedback
Home
Scholarly Works
Countercurrent extraction in a rising film column
Journal article

Countercurrent extraction in a rising film column

Abstract

A 5 cm diameter countercurrent extraction column has been operated in film flow conditions, using the system: water (continuous), kerosene (rising film), acetic acid (transferring solute). The film was supported by vertical Teflon wires (0.80 mm dia.) or perforated Teflon plates. The wire arrangement, with suitable cross-pieces to promote surface renewal, gave the best performance. The film column provides a constant interfacial area and very …

Authors

He W; Baird MHI

Journal

Chemical Engineering Research and Design, Vol. 67, No. 1, pp. 96–109

Publication Date

January 1, 1989

ISSN