Cracking and corrosion performance of composite tubes and air port designs in a kraft recovery boiler
Abstract
Alternative composite tube systems fabricated into two different port designs were installed in a kraft recovery boiler to evaluate their effectiveness in solving a composite tube cracking problem. Test ports have been examined for cracking and corrosion of the cladding/overlay every six months since the time of their installation. Test ports with co-extruded modified A825/carbon steel composite tubes, and port design designated "B" were the …
Authors
Kish JR; Singbeil DL; Keiser JR; Wensley A; Jetté F
Volume
106
Pagination
pp. 30-35
Publication Date
November 1, 2005
Conference proceedings
Pulp and Paper Canada
Issue
11
ISSN