Conference
Investigation of a High Precision Hydrostatic Actuation System: How Nonlinearities Affect Its Performance
Abstract
A prototype Electro-Hydraulic Actuator (EHA) system has demonstrated a positional accuracy in the order of 100 nanometer. Linearized models of the EHA have been formulated and have shown reasonable correlation to the performance of the physical EHA. However, these models predict zero steady state error (an impossible situation given the physical limitations of seals, friction etc.). Further, the prototype EHA indicates that the cut-off …
Authors
Li W; Burton R; Habibi S
Pagination
pp. 175-183
Publisher
ASME International
Publication Date
January 1, 2007
DOI
10.1115/imece2007-41650
Name of conference
Volume 4: Design, Analysis, Control and Diagnosis of Fluid Power Systems