Home
Scholarly Works
Coplanar capacitance sensors for detecting water...
Journal article

Coplanar capacitance sensors for detecting water intrusion in composite structures

Abstract

Composite materials are becoming more affordable and widely used for retrofitting, rehabilitating and repairing reinforced concrete structures designed and constructed under older specifications. However, the mechanical properties and long-term durability of composite materials may degrade severely in the presence of water intrusion. This study presents a new non-destructive evaluation (NDE) technique for detecting the water intrusion in composite structures by evaluating the dielectric properties of different composite system constituent materials. The variation in the dielectric signatures was employed to design a coplanar capacitance sensor with high sensitivity to detect such defects. An analytical model was used to study the effect of the sensor geometry on the output signal and to optimize sensor design. A finite element model was developed to validate analytical results and to evaluate other sensor design-related parameters. Experimental testing of a concrete specimen wrapped with composite laminate and containing a series of pre-induced water intrusion defects was conducted in order to validate the concept of the new technique. Experimental data showed excellent agreement with the finite element model predictions and confirmed sensor performance.

Authors

Nassr AA; Ahmed WH; El-Dakhakhni WW

Journal

Measurement Science and Technology, Vol. 19, No. 7,

Publisher

IOP Publishing

Publication Date

July 1, 2008

DOI

10.1088/0957-0233/19/7/075702

ISSN

0957-0233

Contact the Experts team