Experts has a new look! Let us know what you think of the updates.

Provide feedback
Home
Scholarly Works
Novel tangential-flow countercurrent cascade...
Journal article

Novel tangential-flow countercurrent cascade ultrafiltration configuration for continuous purification of humanized monoclonal antibody

Abstract

This paper discusses the use of a novel tangential-flow, three-stage, countercurrent cascade ultrafiltration configuration for continuous purification of monoclonal antibody Campath-1H from simulated mammalian cell culture supernatant. The main limitation of conventional ultrafiltration based bioseparation, particularly when using a single-stage system is the trade-off between recovery and purity. The aim of this study was to try to improve …

Authors

Mohanty K; Ghosh R

Journal

Journal of Membrane Science, Vol. 307, No. 1, pp. 117–125

Publisher

Elsevier

Publication Date

1 2008

DOI

10.1016/j.memsci.2007.09.010

ISSN

0376-7388