Abstract
The transient performance of an integrated radiant syngas cooler (RSC) of an entrained‐bed gasifier and steam methane reformer (SMR) is investigated. Base‐case designs using either co‐current or counter‐current configurations are subjected to operating transients to evaluate the feasibility to transition to new steady states. Each system, under open loop, is subjected to changes in key variables of the SMR feed on the tube side and disturbances …