Journal article
EMF Measurements of the Na-Si System
Abstract
The electromotive force (EMF) of galvanic cells with β-alumina solid electrolyte was measured to determine the phase relations and thermodynamic properties of the Na-Si binary system below 800 °C. Na was added by coulometric titration to cells containing known amounts of silicon. The galvanic cells sealed with Corning 1720 Kovar glass had unpredictable lifetimes, lasting from several days to less than one reading. A new ceramic seal consisting …
Authors
Mali A; Petric A
Journal
Journal of Phase Equilibria and Diffusion, Vol. 34, No. 6, pp. 453–458
Publisher
Springer Nature
Publication Date
December 2013
DOI
10.1007/s11669-013-0259-5