In this work, a novel sensitive composition of Fricke radio-chromic gel dosimeter based on polyvinyl alcohol (PVA), xylenol orange (XO), and physical cross-linking agent gellan gum (GG) is presented and evaluated with two optically detection methods. The Fricke dosimeter was irradiated up to 30Gy using medical linear accelerator and analyzed optically using ultraviolet visible (UV–Vis) spectrophotometry technique at wavelengths of 585 nm (i.e., …

Authors

Eyadeh MM; Rabaeh KA; Alshomali LS; Diamond KR; Oglat AA

Journal

Radiation Measurements, Vol. 177, ,

Publisher

Elsevier

Publication Date

September 2024

DOI

10.1016/j.radmeas.2024.107263