Home
Scholarly Works
Tendon cross‐sectional area on magnetic resonance...
Journal article

Tendon cross‐sectional area on magnetic resonance imaging and anthropometric characteristics can be used to predict insufficient four‐strand hamstring autograft diameter in anterior cruciate ligament reconstruction: A systematic review

Abstract

PURPOSE: To evaluate the utility of semitendinosus tendon (ST) and gracilis tendon (GT) cross-sectional area (CSA) on magnetic resonance imaging (MRI) and anthropometric characteristics in preoperative estimation of graft diameter in patients undergoing anterior cruciate ligament reconstruction (ACLR) with four-strand hamstring autografts. METHODS: Three databases were searched on 29 August 2023. The authors adhered to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) and R-AMSTAR (Revised Assessment of Multiple Systematic Review) guidelines and the Cochrane Handbook for Systematic Reviews of Interventions. Data on demographics, anthropometric characteristics, imaging techniques, tendon CSA, correlation coefficients, sensitivities, specificities, regression models and cutoffs for predicting intraoperative graft diameters above 8 mm were recorded. RESULTS: Forty-six studies comprising 4140 patients were included. Twelve of 19 (63.2%) studies reporting on ST + GT CSA found a moderate to very high correlation with intraoperative graft diameter. Five of 10 (50%) and one of seven (14.3%) studies reporting on ST CSA and GT CSA, respectively, found a moderate to high correlation with intraoperative graft diameter. Cutoffs of ST + GT CSA for predicting graft diameters above 8 mm ranged from 15.8 to 31.2 mm2. Nine of 35 (25.7%) studies that reported on height found a moderate to very high correlation with graft diameter. Seven of 33 (21.2%) studies reporting on weight found a moderate correlation with graft diameter. CONCLUSION: Of the MRI parameters assessed, ST + GT CSA was the most reliable predictor of graft diameter. However, cutoffs, sensitivities, and specificities for predicting diameters above 8 mm were highly variable. Anthropometric characteristics in general were less predictive of graft diameter than MRI parameters. This information can be used by clinicians to predict patients at risk for ACLR failure due to insufficient graft size. LEVEL OF EVIDENCE: Level IV.

Authors

Vivekanantha P; Grzela P; Wong S; Mansour F; Khalik HA; Johnson J; Hantouly A; de D

Journal

Knee Surgery Sports Traumatology Arthroscopy, Vol. 32, No. 6, pp. 1470–1491

Publisher

Wiley

Publication Date

June 1, 2024

DOI

10.1002/ksa.12179

ISSN

0942-2056

Contact the Experts team