Journal article
Investigating the TEPC radiation quality factor response for low energy accelerator based clinical applications
Abstract
The use of a tissue equivalent proportional counter (TEPC) filled with propane based tissue equivalent gas simulating a 2 microm diameter tissue sphere has been investigated to estimate the radiation quality factor of the neutron fields used in in vivo neutron activation measurements at the McMaster University 3 MV Van de Graaff accelerator. The counter response to estimate the effective quality factor based on the definitions of Q(L) provided …
Authors
Aslam; Prestwich WV; McNeill FE; Waker AJ
Journal
Radiation Protection Dosimetry, Vol. 103, No. 4, pp. 311–322
Publisher
Oxford University Press (OUP)
Publication Date
March 1, 2003
DOI
10.1093/oxfordjournals.rpd.a006148
ISSN