Conference
Effect Of Frequency On Electrohydrodynamic Enhanced Tube-Side Condensation
Abstract
The effect of high voltage AC electric fields on two-phase flow regime redistribution for flowing refrigerant HFC-134a has been investigated. In particular, the effect of the frequency of an applied square wave between 0 and 8 kV was studied. The flow visualization test section at the exit of the heat exchanger was made of quartz tube coated with an electrically grounded transparent conductive film of Tin Oxide. The flow regime transitions …
Authors
Sadek H; Cotton JS; Ching CY; Shoukri M
Pagination
pp. 145-149
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Publication Date
January 1, 2007
DOI
10.1109/theta.2007.363428
Name of conference
2007 International Conference on Thermal Issues in Emerging Technologies: Theory and Application