Experts has a new look! Let us know what you think of the updates.

Provide feedback
Home
Scholarly Works
Axial dispersion in a pulsed plate column
Journal article

Axial dispersion in a pulsed plate column

Abstract

Abstract A technique involving the indicator colour change in an acidbase reaction has been used to measure axial dispersion coefficients in a 15 cm diameter pulsed column. Data have been obtained mainly for single phase (aqueous) flow with two different types of plate at two different spacings. With coarsely perforated plates, the dispersion coefficient is proportional to (amplitude) 2 times frequency, but semicircular unperforated baffle …

Authors

Baird MHI

Journal

The Canadian Journal of Chemical Engineering, Vol. 52, No. 6, pp. 750–757

Publisher

Wiley

Publication Date

December 1974

DOI

10.1002/cjce.5450520608