Composite synthetic bones are widely used in orthopaedic research. They offer many advantages over post mortem human specimens, including low inter-specimen variability in both geometry and material properties, ready availability, and ease of handling, storage and disposal. Fourth generation models of Sawbones® (Pacific Research Laboratories, Inc., Vashon, WA, USA) are made using a short glass fiber reinforced epoxy resin injected around a core of rigid polyurethane foam. These composite bones have been previously validated to replicate natural bone response at a quasi-static rate [1].Copyright © 2010 by ASME

Authors

Quenneville CE; Greeley GS; Dunning CE

Pagination

pp. 805-806

Publisher

ASME International

Publication Date

June 16, 2010

DOI

10.1115/sbc2010-19274

Name of conference

ASME 2010 Summer Bioengineering Conference, Parts A and B