Abstract
Discs of biocompatible glass ionomer cements were prepared for Hertzian indentation and subsequent fracture analyses. Specifically, 2 × 10 mm samples for reproducing bottom-initiated radial fracture, complemented by 0.2 × 1 mm samples for optimal resolution with X-ray micro tomography (μCT), maintaining dimensional ratio. The latter allowed for accurate determination of volumetric-porosity of the fully cured material, fracture-branching through …
Authors
Tian KV; Nagy PM; Chass GA; Fejerdy P; Nicholson JW; Csizmadia IG; Dobó-Nagy C
Journal
Journal of Materials Science: Materials in Medicine, Vol. 23, No. 3, pp. 677–685