This paper presents the findings of an experimental study that investigated the response properties of segmental cantilever columns incorporating internal unbonded posttensioning (PT) and slip-dominant (SD) joints. The SD joints exhibited controlled sliding that provided energy dissipation with low damage. All joints of these columns, except for the bottom one, were designed to be SD. The bottom joint was designed to be rocking dominant (RD) and exhibited rocking that offered self-centering to the system. Design objectives and equations are presented. These equations were used for the design of a large-scale cantilever column that was subjected to reverse lateral cyclic loading at its top end, reaching a maximum drift ratio of 14.9%. At small drift ratios (≤3%), the response was dominated by sliding of the SD joints that provided energy dissipation (damping). For medium drift ratios (between 3 and 10%), rocking at the bottom joint increased and provided self-centering properties to the system. For large drift ratios (>10%), the self-centering properties decreased, but the damping properties remained practically constant. Rocking at the SD joints remained small at all times. Minor spalling was observed in the SD joints, while concrete crushing was observed at the bottom joint.

Authors

Sideris P; Aref AJ; Filiatrault A

Journal

Journal of Bridge Engineering, Vol. 19, No. 10,

Publisher

American Society of Civil Engineers (ASCE)

Publication Date

October 1, 2014

DOI

10.1061/(asce)be.1943-5592.0000605

ISSN

1084-0702

Labels

Fields of Research (FoR)

Contact the Experts team