Journal article
On the Interaction Between Power System Configuration and Industrial Rectifier Harmonic Interference: A Practical Case Study
Abstract
Department of Electrical and Computer Engineering A severe interference problem caused by a large rectifier installation is studied. The interaction between harmonic emission level and power system impedance matching is described. An elegant solution involving corrective measures on each of the plants: customer, power system and communication circuits, are proposed. The dangers of creating new problems with single approaches is stressed out, …
Authors
Szabados B
Journal
IEEE Transactions on Power Apparatus and Systems, Vol. PAS-101, No. 8, pp. 2762–2769
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Publication Date
8 1982
DOI
10.1109/tpas.1982.317515
ISSN
0018-9510