Abstract

BACKGROUND: Previous studies have suggested that the incidence of retinopathy is lower in preterm infants with exposure to reduced levels of oxygenation than in those exposed to higher levels of oxygenation. However, it is unclear what range of oxygen saturation is appropriate to minimize retinopathy without increasing adverse outcomes. METHODS: We performed a randomized trial with a 2-by-2 factorial design to compare target ranges of oxygen …

Authors

Carlo WA; Finer NN; Walsh MC; Rich W; Gantz MG; Laptook AR; Yoder BA; Faix RG; Das A; Poole WK

Journal

The New England Journal of Medicine, Vol. 362, No. 21, pp. 1959–1969

Publisher

Massachusetts Medical Society

Publication Date

May 27, 2010

DOI

10.1056/nejmoa0911781

ISSN

0028-4793