Journal article
The effects of dual‐orifice air‐ring design on blown film cooling
Abstract
Abstract Numerical simulations of turbulent air flows tangentially impinging on blown film bubbles have been carried out. The cooling air is assumed to originate from a dualorifice adjustable air‐ring. The streamline patterns and heat fluxes are determined through a finite volume numerical technique for modeling of turbulent air flow. It is shown that cooling efficiency is critically sensitive to the air‐ring design as minor modifications cause …
Authors
Sidiropoulos V; Vlachopoulos J
Journal
Polymer Engineering & Science, Vol. 40, No. 7, pp. 1611–1618
Publisher
Wiley
Publication Date
7 2000
DOI
10.1002/pen.11292
ISSN