Home
Scholarly Works
Sind hochverstärkende Film-Folien-Kombinationen...
Journal article

Sind hochverstärkende Film-Folien-Kombinationen zur Detektion feiner interstitieller Lungenveränderungen geeignet?

Abstract

Exposures of an anthropomorphic thorax phantom in posteroanterior projection were made using a focus-film distance of 200 cm and 125 kV with film-screen combinations in class 200 (Curix RP 1L/MR 200) and class 400 (Curix ST-L/Regular). Pathomorphological structures of the lung parenchyma of fine nodular, linear and reticular types were simulated by suitable materials. A ROC analysis including a t-test showed no significant difference in the evaluation of these structural details (p > 0.05). In order to describe image quality for the two film-screen systems, density curves, sigma D-curves and modulation transfer function (MTF) were determined. The only demonstrable difference was reduced MTF of 10-15% for the higher intensification film-screen combination with a resulting poorer resolution of 3.7 l/mm (for the 400 system) compared with 4.3 l/mm for the 200 system.

Authors

Müller R-D; John V; Voß M; Buddenbrock B; Blendl C; Hirche H; Ewen K; Löhr E

Journal

RöFo, Vol. 159, No. 07, pp. 54–59

Publisher

Thieme

Publication Date

July 1, 1993

DOI

10.1055/s-2008-1032721

ISSN

1438-9029
View published work (Non-McMaster Users)

Contact the Experts team