Experts has a new look! Let us know what you think of the updates.

Provide feedback
Home
Scholarly Works
Leaf temperature error from heat conduction along...
Journal article

Leaf temperature error from heat conduction along thermocouple wires

Abstract

Heat conduction through the wires is one source of thermocouple (TC) error. Leaf temperature measurement may be affected by this error if the leaf-to-air temperature difference is large and contact between TC and leaf is inadequate. Selection of small diameter TCs with low thermal conductivity, as well as good contact with the leaf, are possible solutions to the problem. A laboratory experiment was carried out to determine conduction error as a …

Authors

Tarnopolsky M; Seginer I

Journal

Agricultural and Forest Meteorology, Vol. 93, No. 3, pp. 185–194

Publisher

Elsevier

Publication Date

March 1999

DOI

10.1016/s0168-1923(98)00123-3

ISSN

0168-1923